laptop and a wrench

Bogue

Validating topology for specific dirty areas in a utility network returns Error 999999 using the geoprocessing tool and returns the error message, "Edit operation failed. ERROR:" when validating topology using the ribbon.

Dernière publication: February 17, 2022 ArcGIS Utility Network
Numéro d’ID de bogue BUG-000146866
EnvoiFebruary 15, 2022
Dernière modificationJune 5, 2024
S’applique àArcGIS Utility Network
Version trouvée4
Système d’exploitationWindows OS
Version du système d’exploitationN/A
StatutDuplicate

Informations supplémentaires

This is a duplicate of BUG-000146998. The cause of this issue is the same as outlined in BUG-000146998. During reconcile, delete/update conflicts that leave a feature or object with a deleted dirty area and feature are encountered. However, if the deleted feature or object is restored via Conflict Manager, it can create a scenario where the dirty area becomes out of sync. This leads to failures during validation such as those outlined in the case for this bug.

Étapes pour reproduire

ID de bogue: BUG-000146866