| Numéro d’ID de bogue |
BUG-000172481 |
| Envoi | November 21, 2024 |
| Dernière modification | January 5, 2025 |
| S’applique à | ArcGIS Pro |
| Version trouvée | 3.3 |
| Système d’exploitation | Windows OS |
| Version du système d’exploitation | 10.0 64 Bit |
| Statut | As Designed
Après examen par l’équipe de développement, il a été déterminé que ce comportement est prévu. Pour plus d’informations, reportez-vous à la section Informations supplémentaires.
|
Informations supplémentaires
When running an upstream trace, if loops are encountered upstream from the starting point, these will be pulled into the result when Allow Indeterminate Flow is checked. In the provided scenario, the upstream trace encounters a line end which participates in junction junction connectivity associations with 3 fuse devices and another riser, creating a loop. Because Allow Indeterminate Flow is checked (enabled), the features within the loop are returned with the result, because we have no way to determine if the features are upstream or downstream of the starting point. Unchecking (disabling) Allow Indeterminate Flow with the trace returns the expected result and excludes the features from the upstream trace result.
Solution de contournement
Uncheck (disable) Allow Indeterminate Flow when running the upstream trace.
Étapes pour reproduire
ID de bogue: BUG-000172481
Logiciel: