laptop and a wrench

Bogue

Tracing connected features in a Utility Network from a barrier with two terminals does not traverse the opposite terminal.

ArcGIS Pro
Numéro d’ID de bogue BUG-000165667
EnvoiMarch 6, 2024
Dernière modificationJune 5, 2024
S’applique àArcGIS Pro
Version trouvée3.2.2
Système d’exploitationWindows OS
Version du système d’exploitation10.0 64 Bit
StatutAs Designed

Informations supplémentaires

In this scenario, a Condition barrier is configured for both the IN and OUT terminals (Asset Group is equal to Indeterminate) on the device, whereas a Starting point is only present on the IN terminal. Ignore Starting Points at Barriers is honored properly in this case but does not apply to the OUT terminal which also has a barrier present. This is what led to the trace result reported.

Solution de contournement

Place a second starting point on the other terminal (so that both the IN and OUT terminals have starting points) and run the trace again with the Ignore Barriers at Starting Points parameter checked.

Étapes pour reproduire

ID de bogue: BUG-000165667

Logiciel:

  • ArcGIS Pro

Recevoir une notification lorsque le statut d’un bogue change

Télécharger l’application Esri Support

En savoir plus sur ce sujet

Obtenir de l’aide auprès des experts ArcGIS

Contacter le support technique

Télécharger l’application Esri Support

Accéder aux options de téléchargement