There are issues with the projection engine (ESRI.ArcGIS.Runtime.PE.dll) while re-projecting a Lambert Conformal Conic projection to the Geographic Coordinate system (GCS).

Dernière publication: February 7, 2020 ArcGIS Engine
Numéro d’ID de bogue BUG-000102815
EnvoiFebruary 9, 2017
Dernière modificationJune 5, 2024
S’applique àArcGIS Engine
Version trouvée10.5
Système d’exploitationWindows OS
Version du système d’exploitation7
StatutKnown Limit

Informations supplémentaires

The issue with the projected coordinate system definition is the standard parallel 1 = 0.0. It has to be omitted or set to 19.0, the same value as the latitude of origin. Alternatively, given a standard parallel 1 of 0.0 and no standard parallel 2 parameter, use the Mercator algorithm instead. That is not set up in 10.5, but is going to be in the future release in 2020. We are planning to add a specific Lambert Conformal Conic 1SP definition which is easier to define a 1SP case.