laptop and a wrench

Bogue

The user needs to set failover_on_primary_stop=true for HA ArcGIS Datastores

ArcGIS Data Store
Numéro d’ID de bogue BUG-000172945
EnvoiDecember 10, 2024
Dernière modificationJune 16, 2025
S’applique àArcGIS Data Store
Version trouvée11.3
Système d’exploitationWindows Server
Version du système d’exploitation2022
StatutNon-Reproducible

Informations supplémentaires

The issue cannot be reproduced at this time. If you are experiencing this behavior, please contact Esri Support Services, as a new reproduction case is required to further the investigation.

Solution de contournement

1.Go to to arcgisdatastore>etc>datastore.properties on both datastore machines.

2.You should see an option that says: failover_on_primary_stop=false (default)

This option should be set to true, so replace FALSE with TRUE and save the file.

3.Navigate also to C:\Program Files\ArcGIS\DataStore\framework\etc\datastore.properties, and change the same option found in this file to TRUE as well for both datastore machines.

4.Restart the Datastore Services.

5.Test failover and it should be successful this time around.