laptop and a wrench

Bogue

The Portal for ArcGIS 'storageQuota' size is not increased after an upgrade.

Dernière publication: March 4, 2020 Portal for ArcGIS
Numéro d’ID de bogue BUG-000122915
EnvoiJune 7, 2019
Dernière modificationJune 5, 2024
S’applique àPortal for ArcGIS
Version trouvée10.7
Système d’exploitationWindows OS
Version du système d’exploitation2016 64 Bit
Version de correction10.8
StatutFixed

Solution de contournement

Save the following script as a batch file, and run on the Portal for ArcGIS machine to update the 'storageQuota'.

 

"C:\Program Files\ArcGIS\Portal\framework\runtime\pgsql\bin\psql.exe" -U <iaa> -p 7654 -d gwdb -c "UPDATE public.gw_accounts SET quota=10995116277760 WHERE id='0123456789ABCDEF';"

 

  • Replace <iaa> with the Portal for ArcGIS primary site admin account username.
  • Using the notepad++, and save the script as a .bat file.
  • Copy the .bat to the Portal for ArcGIS machine.
  • Open command prompt as an administrator, and run the .bat file.
  • When prompted, supply the Portal for ArcGIS primary site admin password.
  • Restart the Portal for ArcGIS windows service to re-issue the self call.
  • Navigate to ArcGIS Portal Directory > Home > Portals > Self, and verify if the 'storageQuota' has been updated.
    • The new 'storageQuota' is 10995116277760.

 

Note: It is highly recommended to back up Portal for ArcGIS before running through this workflow.

Étapes pour reproduire

ID de bogue: BUG-000122915