laptop and a wrench

Bogue

Reconcile fails on a branch version, returning the error message "Version is still in use." because the version lock on the branch version is not released after an edit session ends in a different ArcGIS Pro session.

Dernière publication: December 1, 2020 ArcGIS Pro
Numéro d’ID de bogue BUG-000135097
EnvoiNovember 2, 2020
Dernière modificationJuly 11, 2025
S’applique àArcGIS Pro
Version trouvée2.6.2
Système d’exploitationWindows OS
Version du système d’exploitation10.0 64 Bit
Version de correction2.6.4
StatutFixed

Solution de contournement

Add the Utility Network data to the project by following the steps below:

  1. On the Catalog tab, select Portal.
  2. Select My Organization.
  3. Right-click the feature layer.
  4. Add the data to the new map.
  5. Close the previous ArcGIS Pro session to remove the version lock when another ArcGIS Pro version session tries to reconcile it from another ArcGIS Pro version session.

Étapes pour reproduire