laptop and a wrench

Bogue

Once "Out of memory" error is generated without using hierarchy option, any subsequent route solve with hierarchy option will result in "Out of memory" error until service is restarted.

Dernière publication: August 25, 2014 ArcGIS Server (.NET)
Numéro d’ID de bogue NIM049698
EnvoiOctober 9, 2009
Dernière modificationApril 2, 2025
S’applique àArcGIS Server (.NET)
Version trouvée9.3.1
Système d’exploitationWindows OS
Version du système d’exploitation2003 64 Bit
StatutKnown Limit

Informations supplémentaires

No Public Explanation

Solution de contournement

this is a known issue in 9.3.1 NAServer. Workaround is to manually specify in the NAServer properties of the deployed configuration the <Route_AutoHierarchyThreshold> parameter, which would prevent clients from solving exact routes on long distances.e.g.: <Extension> <TypeName>NAServer</TypeName> <Enabled>true</Enabled> <Properties> <Route_AutoHierarchyThreshold>0.055</Route_AutoHierarchyThreshold> ...0.055 - is in the native network dataset units (decimal degrees in this case) If max side of stops' envelope is bigger than this value, solve will be hierarchical.

Étapes pour reproduire

ID de bogue: NIM049698

Logiciel:

  • ArcGIS Server (.NET)

Recevoir une notification lorsque le statut d’un bogue change

Télécharger l’application Esri Support

En savoir plus sur ce sujet

Obtenir de l’aide auprès des experts ArcGIS

Contacter le support technique

Télécharger l’application Esri Support

Accéder aux options de téléchargement