laptop and a wrench

Bogue

In ArcGIS Enterprise 11.5 Map Viewer, the 'Image measurement' tool remains disabled for oriented imagery layers with the orientation accuracy property defined.

Portal for ArcGIS
Numéro d’ID de bogue BUG-000180541
EnvoiOctober 29, 2025
Dernière modificationDecember 2, 2025
S’applique àPortal for ArcGIS
Version trouvée11.5
Système d’exploitationWindows Server
Version du système d’exploitation2025
StatutKnown Limit

Informations supplémentaires

The measurement tool required nine semicolon-separated values instead of the eight specified in the documentation. This issue was known to occur in ArcGIS Enterprise 11.5 and ArcGIS Online 2025 R01, and it has been resolved in ArcGIS Enterprise 12.0 and the latest version of ArcGIS Online.

Solution de contournement

As a workaround, add an additional ;0 at the end of the OrientationAccuracy property. For example, if the current value is 5;10;5;5;5;0;0;1, update the value to 5;10;5;5;5;0;0;1;0. This workaround should work well in ArcGIS Enterprise 11.5.

Étapes pour reproduire

ID de bogue: BUG-000180541

Logiciel:

  • Portal for ArcGIS

Recevoir une notification lorsque le statut d’un bogue change

Télécharger l’application Esri Support

En savoir plus sur ce sujet

Obtenir de l’aide auprès des experts ArcGIS

Contacter le support technique

Télécharger l’application Esri Support

Accéder aux options de téléchargement