laptop and a wrench

Bogue

Failed to update SDO_GEORASTER SRID for SDO_GEORASTER objects in ArcSDE raster catalog created and loaded by ArcCatalog.

Dernière publication: August 25, 2014 ArcSDE/Enterprise Geodatabase
Numéro d’ID de bogue NIM044808
EnvoiApril 28, 2009
Dernière modificationApril 2, 2025
S’applique àArcSDE/Enterprise Geodatabase
Version trouvée9.3
Système d’exploitationWindows OS
Version du système d’exploitation2003
StatutWill Not Be Addressed

Informations supplémentaires

We apologize that we were unable to address this issue within the current product support cycle. If the issue continues to affect your work in a supported release, please contact Technical Support.

Solution de contournement

To get appropriate values for 1, 2, and 3 for each image, here is an example:RAS@ORCL>select objectid, sdo_geor.getSRS(raster) SRS from sdo_cat11g where objectid = 3; OBJECTID SRS(ISREFERENCED, ISRECTIFIED, ISORTHORECTIFIED, SRID, SPATIALRESOLUTION, SPATIA------------ ------------------------------------------------------------------------------------- 3 SDO_GEOR_SRS('TRUE', 'TRUE', NULL, 0, SDO_NUMBER_ARRAY(.000277778, .000277778 ), NULL, 0, 0, 0, 0, 0, 0, 1, 1, 1, 1, 1, NULL, NULL, NULL, SDO_NUMBER_ARRAY(1, 2, 1, 3, 169205.5, 0, -3600), SDO_NUMBER_ARRAY(1, 0, 0, 1, 1), SDO_NUMBER_ARRAY( 1, 2, 1, 3, 360005.5, 3600, 0), SDO_NUMBER_ARRAY(1, 0, 0, 1, 1))There are 3 places to modify for the images you sent me:1. The srs.srid, set it to be 42692. The srs.rowNumerator:SDO_NUMBER_ARRAY(1, 2, 1, 3, 169205.5, 0, -3600) ---> just keep the original values3. The srs.columnNumerator: SDO_NUMBER_ARRAY(1, 2, 1, 3, 360005.5, 3600, 0) ---> just keep the original valuesThe function call:=======================================================DECLARE grobj sdo_georaster; srs sdo_geor_srs; BEGINSELECT raster INTO grobj FROM sdo_cat11g WHERE objectid=3;srs := sdo_geor.getSRS(grobj);srs.isReferenced := 'TRUE';srs.isRectified := 'TRUE';srs.isOrthoRectified := null;srs.srid := 4269;srs.spatialResolution := sdo_number_array(0.000277778, 0.000277778);srs.rowOff := 0;srs.columnOff := 0;srs.xOff := 0;srs.yOff := 0;srs.zOff := 0;srs.rowScale := 1;srs.columnScale := 1;srs.xScale := 1;srs.yScale := 1;srs.zScale := 1;srs.rowNumerator := SDO_NUMBER_ARRAY(1, 2, 1, 3, 169205.5, 0, -3600);srs.rowDenominator := SDO_NUMBER_ARRAY(1, 0, 0, 1, 1); srs.columnNumerator := SDO_NUMBER_ARRAY(1, 2, 1, 3, 360005.5, 3600, 0);srs.columnDenominator := SDO_NUMBER_ARRAY(1, 0, 0, 1, 1); sdo_geor.setSRS(grobj, srs); UPDATE sdo_cat11g SET raster = grobj WHERE objectid=3;COMMIT;END;/=======================================================Then, user can validate the georaster object, validate the schema, and then build the spatial index.

Étapes pour reproduire

ID de bogue: NIM044808