laptop and a wrench

Bogue

Enabling archiving on a feature dataset that contains topology fails with Network I/O error.

Dernière publication: August 25, 2014 ArcSDE/Enterprise Geodatabase
Numéro d’ID de bogue NIM044630
EnvoiApril 24, 2009
Dernière modificationApril 2, 2025
S’applique àArcSDE/Enterprise Geodatabase
Version trouvée9.3
Système d’exploitationWindows OS
Version du système d’exploitation2003 64 Bit
Version de correction9.4
StatutFixed

Solution de contournement

Workaround:***********1) Make sure there is a good backup of the feature dataset and no one is accessing that feature dataset.2) Reconcile and post all the versions to SDE.DEFAULT and delete the versions except SDE.DEFAULT and then compress the geodatabase to state 0 so that all the edits are pushed to SDE.DEFAULT version.http://support.esri.com/index.cfm?fa=knowledgebase.techarticles.articleShow&d=291603) Save topology rules.4) Delete topology.5) Copy/Paste feature dataset.6) Recreate topology with saved rules. Please make sure to choose "No" option when it asks "Do you need to specify a configuration keyword?" 7) Validate topology.8) Register the feature dataset as versioned.9) Enable Archiving.

Étapes pour reproduire

ID de bogue: NIM044630

Logiciel:

  • ArcSDE/Enterprise Geodatabase

Recevoir une notification lorsque le statut d’un bogue change

Télécharger l’application Esri Support