laptop and a wrench

Bogue

Connectivity rules are not recognized after un-assigning a user-defined terminal configuration in a utility network.

ArcGIS Pro
Numéro d’ID de bogue BUG-000167417
EnvoiMay 13, 2024
Dernière modificationFebruary 14, 2025
S’applique àArcGIS Pro
Version trouvée3.2.2
Système d’exploitationWindows OS
Version du système d’exploitation10.0 64 Bit
StatutAs Designed

Informations supplémentaires

The invalid connectivity error is expected in this scenario as the existing connectivity rules reference terminal connections that no longer exist. Running Set Terminal Configuration does not impact the rule set, as a result the J-E rules that references specific terminals are no longer valid after modifying the terminal configuration. If the terminal configuration is altered, specify a single terminal configuration. Existing rules must be deleted, and new ones are created that does not reference the terminals.

Solution de contournement

 Use the Add Rule tool to create new junction-edge connectivity rules. Use the Delete Rule tool to remove invalid rules that reference the removed terminals.

Étapes pour reproduire

ID de bogue: BUG-000167417