After failover, if an incremental backup is requested but a full backup has not been run, run a full backup instead of an incremental.

Dernière publication: April 25, 2022 Portal for ArcGIS
Numéro d’ID de bogue BUG-000124785
EnvoiAugust 26, 2019
Dernière modificationFebruary 14, 2023
S’applique àPortal for ArcGIS
Version trouvée10.6.1
Plateforme serveurWindows OS
Plateforme client2016 64 Bit
Version Fixed10.8
StatutFixed

Solution de contournement

There are 2 workarounds:

  • Set the backup location to a shared location. Since both data store machines can access the backup location for the data store that stores incremental snapshots, they are able to avoid issues when an incremental backup is requested after a failover.
  • Run a full backup manually. Note that if the backup location is not in a shared location that both data store machines can access, the issue may occur if the data store needs to failover again.

Étapes pour reproduire

ID de bogue: BUG-000124785