laptop and a wrench

Error

When converting a feature class from PGDB to SDE, a field type Float converts to a Double with extra values.

Última publicación: August 25, 2014 No Product Found
Número de ID del error NIM010927
EnviadoAugust 13, 2007
Última modificaciónApril 28, 2025
Relacionado conNo Product Found
Versión encontrada9.2
EstadoWill Not Be Addressed

Información adicional

No Public Explanation

Solución alternativa

1. Create an empty feature class in SDE geodatabase with same spatial reference as that of the PGDB feature class.2. While creating, Import the fields from the PGDB feature class.3. For Float fields, choose precision and scale as per the requirement (say, precision-5, scale-2)4. Click “Finish” to create the feature class.5. Check again by right clicking the feature class that the Float fields are maintained.6. Now, load the data into this feature class from the PGDB feature class by simple data loader in ArcCatalog. Right click on the feature class? Load Data7. This method retains the original names of the fields.Per Nana Dei:For SQL Server: When the column is created with the ‘REAL’ data type, it shows as Float from ArcCatalogHowever, when it is created as ‘Float’ from ArcCatalog is shows as DOUBLE in ArcCatalog 10 and NUMERIC in SQL Server.

Pasos para reproducir

ID del error: NIM010927