laptop and a wrench

Error

Upstream traces return incorrect or misleading results

ArcGIS Pro
Número de ID del error BUG-000172481
EnviadoNovember 21, 2024
Última modificaciónJanuary 5, 2025
Relacionado conArcGIS Pro
Versión encontrada3.3
Sistema operativoWindows OS
Versión de sistema operativo10.0 64 Bit
EstadoAs Designed

Información adicional

When running an upstream trace, if loops are encountered upstream from the starting point, these will be pulled into the result when Allow Indeterminate Flow is checked. In the provided scenario, the upstream trace encounters a line end which participates in junction junction connectivity associations with 3 fuse devices and another riser, creating a loop. Because Allow Indeterminate Flow is checked (enabled), the features within the loop are returned with the result, because we have no way to determine if the features are upstream or downstream of the starting point. Unchecking (disabling) Allow Indeterminate Flow with the trace returns the expected result and excludes the features from the upstream trace result.

Solución alternativa

Uncheck (disable) Allow Indeterminate Flow when running the upstream trace.