laptop and a wrench

Error

Tracing connected features in a Utility Network from a barrier with two terminals does not traverse the opposite terminal.

ArcGIS Pro
Número de ID del error BUG-000165667
EnviadoMarch 6, 2024
Última modificaciónJune 5, 2024
Relacionado conArcGIS Pro
Versión encontrada3.2.2
Sistema operativoWindows OS
Versión de sistema operativo10.0 64 Bit
EstadoAs Designed

Información adicional

In this scenario, a Condition barrier is configured for both the IN and OUT terminals (Asset Group is equal to Indeterminate) on the device, whereas a Starting point is only present on the IN terminal. Ignore Starting Points at Barriers is honored properly in this case but does not apply to the OUT terminal which also has a barrier present. This is what led to the trace result reported.

Solución alternativa

Place a second starting point on the other terminal (so that both the IN and OUT terminals have starting points) and run the trace again with the Ignore Barriers at Starting Points parameter checked.

Pasos para reproducir

ID del error: BUG-000165667

Software:

  • ArcGIS Pro

Recibir notificaciones cuando cambie el estado de un error

Descargar la aplicación de soporte de Esri

Descubrir más sobre este tema

Obtener ayuda de expertos en ArcGIS

Contactar con el soporte técnico

Descargar la aplicación de soporte de Esri

Ir a opciones de descarga