laptop and a wrench

Error

The SDO_Geometry table failed to register with ArcSDE because units gets negative values.

Última publicación: August 25, 2014 ArcSDE/Enterprise Geodatabase
Número de ID del error NIM067910
EnviadoMay 9, 2011
Última modificaciónApril 2, 2025
Relacionado conArcSDE/Enterprise Geodatabase
Versión encontrada10.0
Versión corregida10.1
EstadoFixed

Información adicional

Fixed with new registration workflow (ArcCatalog) in 10.1

Solución alternativa

Specifying more appropriate metadata extents (-180,180, 0.005 and -90,90, 0.005 successfully register)Specifying the offsets and the scale at registration is always preferable to allowing SDE to determine what appropriate values are (-x -180,-90,1000000). SDE will “guess” at these values, but the user should know their data better then SDE could.

Pasos para reproducir

ID del error: NIM067910

Software:

  • ArcSDE/Enterprise Geodatabase

Recibir notificaciones cuando cambie el estado de un error

Descargar la aplicación de soporte de Esri