laptop and a wrench

Error

The primary portal and the standby portal are no longer accessible after the pg_hba.conf entries are commented out.

Última publicación: November 21, 2019 Portal for ArcGIS
Número de ID del error BUG-000126198
EnviadoOctober 22, 2019
Última modificaciónFebruary 14, 2023
Relacionado conPortal for ArcGIS
Versión encontrada10.7.1
Version Fixed10.8.1
EstadoFixed

Solución alternativa

1.On primary Portal, open the pg_hba.conf and uncomment out the entries (Ex. C:\arcgisportal\db\pg_hba.conf). See below:

 

# IPv4 local connections:

host  all       portaladmin       127.0.0.1/32      md5

host  replication   portaladmin       127.0.0.1/32      md5

# IPv6 local connections:

host  all       portaladmin       ::1/128         md5

host  replication   portaladmin       ::1/128         md5)

 

host gwdb portaladmin portalPrimary.domain.com md5

host gwdb portaladmin portalStandby.domain.com md5

 

host gwdb portaladmin 10.151.10.25 md5

host gwdb portaladmin 10.151.10.26 md5

 

2. Reload Portal for ArcGIS database with the following command, in an administrator command prompt.

  • cd C:\Program Files\ArcGIS\Portal\framework\runtime\pgsql\bin
  • pg_ctl.exe reload -D C:\arcgisportal\db

 

3. Stop and start Portal for ArcGIS' internal database.

  • pg_ctl.exe stop -D C:\arcgisportal\db
  • pg_ctl.exe start -D C:\arcgisportal\db

 

4. You should now be able to access the primary Portal for ArcGIS.

 

5. Repeat Steps 1 through 3 for the standby Portal for ArcGIS.

Pasos para reproducir

ID del error: BUG-000126198

Software:

  • Portal for ArcGIS

Obtener ayuda de expertos en ArcGIS

Contactar con soporte técnico

Descargar la aplicación de soporte de Esri

Ir a las opciones de descarga

Descubrir más sobre este tema