laptop and a wrench

Error

The Flow Accumulation output produces incorrect anomalies when outputted to Float. The count of cells do not increase for identified stretch of cells in the flow path, even if only the previous cell in the main flow path fed into the next cell. The count must increase by 1.

Última publicación: August 19, 2020 ArcGIS for Desktop
Número de ID del error BUG-000097581
EnviadoJuly 6, 2016
Última modificaciónNovember 24, 2020
Relacionado conArcGIS for Desktop
Versión encontrada10.2
EstadoWill Not Be Addressed

Información adicional

We apologize that we were unable to address this issue within the current product support cycle.  If the issue continues to affect your work in a supported release, please contact Technical Support.

Solución alternativa

Set the Flow Accumulation output to Integer.