laptop and a wrench

Error

The Append Routes geoprocessing tool fails and returns the following error, "160145: The field is not nullable.[ASSETTYPE]."

Última publicación: November 6, 2020 Pipeline Referencing – Pro
Número de ID del error BUG-000135023
EnviadoOctober 29, 2020
Última modificaciónJune 5, 2024
Relacionado conPipeline Referencing – Pro
Versión encontrada2.6.2
Sistema operativoWindows OS
Versión de sistema operativo10.0 64 Bit
Versión corregida3.0
EstadoFixed

Solución alternativa

  1. Use 'Append' to load PipelineLine.
  2. Use 'Append' to load LRSnetwork.
  3. Author a script to populate the Centerline_Sequence table. The table holds the cardinality or relationship between PipelineLine: LRSnetwork. Reference: LRS data model—ArcGIS Pro | Documentation 
  4. Generate Calibration Points or Append Calibration Points.
  5. Finally, use 'Generate Routes' to sync up the LRS components.