laptop and a wrench

Error

Specific cameras in Site Scan for ArcGIS have the memory usage incorrectly calculated, leading to missions failing to process with large product sizes.

Última publicación: October 6, 2022 Site Scan for ArcGIS
Número de ID del error BUG-000152389
EnviadoSeptember 16, 2022
Última modificaciónJuly 31, 2024
Relacionado conSite Scan for ArcGIS
Versión encontradaN/A
Sistema operativoWindows OS
Versión de sistema operativo10.0 64 Bit
EstadoKnown Limit

Información adicional

The failure occurred because the process is running out of memory which is by design. There are several factors that can result in hitting memory limits, including the mission size and processing quality. This mission contains three discrete corridors and the result is that the entire mission is extremely large (estimated to be 13 km wide). To avoid this issue, split the mission into three, each containing one set of corridor images. This allows the process to be complete on high quality. In the future, an increase of the memory allowance is considered to support processing of very large areas.