laptop and a wrench

Error

Reconciling a named version after deleting a connectivity association and moving a point introduces an unanticipated large dirty area.

Última publicación: December 2, 2021 ArcGIS Utility Network
Número de ID del error BUG-000141304
EnviadoJuly 8, 2021
Última modificaciónJune 5, 2024
Relacionado conArcGIS Utility Network
Versión encontrada3
Sistema operativoWindows OS
Versión de sistema operativo2019 64 Bit
EstadoAs Designed

Información adicional

Dirty areas are created for the extent of the association when working with Utility Network Version 3. The new model for dirty area management introduced with ArcGIS Pro 2.6 and Utility Network Version 4 works differently and creates dirty areas for the individual features alone and excludes the extent of the association.

Solución alternativa

Upgrade to the Utility Network Version 4 or higher.

For a version 3 network, use the following alternate workflows to avoid the large dirty area. Conduct the entire workflow in the default version.

  • Delete the association in a named version and reconcile or post the change before moving the point.
  • Delete the association in the default version and move the point in the named version.
  • Instead of moving the point, copy and paste the point to a new point, delete the old point, and move the new point to the desired location.

Pasos para reproducir

ID del error: BUG-000141304

Software:

  • ArcGIS Utility Network

Recibir notificaciones cuando cambie el estado de un error

Descargar la aplicación de soporte de Esri

Descubrir más sobre este tema

Obtener ayuda de expertos en ArcGIS

Contactar con el soporte técnico

Descargar la aplicación de soporte de Esri

Ir a opciones de descarga