laptop and a wrench

Error

NITF file does not display correctly within ArcGIS when georeferenced.

Última publicación: August 25, 2014 No Product Found
Número de ID del error NIM004678
EnviadoOctober 6, 2006
Última modificaciónApril 2, 2025
Relacionado conNo Product Found
Versión encontrada9.1
Versión corregida9.3
EstadoFixed

Solución alternativa

Workaround from the user:One difference is that in later versions we write out the BLOCKA TRE. There's a chance that this could be causing the problem. They can disable the writing of the BLOCKA TRE by setting the following registry entry and rechipping. WriteBLOCKA REG_SZ false By default the BLOCKA TRE will be written with every saved or chipped NITF image (if the image contains geo information). If this registry entry is set to false then the BLOCKA TRE will NOT be written. The BLOCKA TRE contains more actual geo corner coordinates than the standard IGEOLO field. .ie Using regedit, this goes under HKEY_LOCAL_MACHINE/SOFTWARE/Sensor Systems/RemoteView/Public string value WriteBLOCKA false

Pasos para reproducir

ID del error: NIM004678

Software:

  • No Product Found

Recibir notificaciones cuando cambie el estado de un error

Descargar la aplicación de soporte de Esri

Descubrir más sobre este tema

Obtener ayuda de expertos en ArcGIS

Contactar con el soporte técnico

Descargar la aplicación de soporte de Esri

Ir a opciones de descarga