IToploogicalOperator::Difference hangs with specific data in a Personal Geodatabase.

Última publicación: August 25, 2014 No Product Found
Número de ID del error NIM000530
EnviadoDecember 8, 2005
Última modificaciónJune 5, 2024
Relacionado conNo Product Found
Versión encontrada9.1
Versión corregida9.2
EstadoFixed

Solución alternativa

Reduce Domain to something more reasonable.NO DEAL WITH ITOPOLOGICALOPERATOR::DIFFERENCEMinX=140.25 MaX=159.499, MinY=-38, MaxX=-18.750.Precision was therefore smaller equalling 111557592. The datas' shapelength was small (0.001).SUCCESSFUL USING ITOPOLOGICALOPERATOR::DIFFERENCE:I then created a new fc (empty) and made a tighter Domain MinX=150 MaxX=152, MinY=-34, MaxX=-32. Precision was now larger: 1073741822.5. ITopologicalOPerator was now successful.