laptop and a wrench

Error

Data published to Portal for ArcGIS with a Float field type will be transformed to esriFieldTypeSingle, altering the field's numeric data.

Portal for ArcGIS
Número de ID del error BUG-000127521
EnviadoDecember 19, 2019
Última modificaciónJanuary 10, 2025
Relacionado conPortal for ArcGIS
Versión encontrada10.7.1
Sistema operativoN/A
Versión de sistema operativoN/A
EstadoAs Designed

Información adicional

This is expected behavior; it is necessary to specify the precision and scale of the dataset. Specifying the precision and scale restricts the range of values and number formats a field can accept, giving greater control. For example, when specifying a float with a precision of 4 and a scale of 2, the field will accept 12.34. If 12.345 is entered into the field, an error message would display, as this exceeds the maximum number of digits and decimal places allowed. On the other hand, when specifying a float with a precision of 5 and a scale of 3, the field will accept 12.345.

Pasos para reproducir

ID del error: BUG-000127521

Software:

  • Portal for ArcGIS

Recibir notificaciones cuando cambie el estado de un error

Descargar la aplicación de soporte de Esri

Descubrir más sobre este tema

Obtener ayuda de expertos en ArcGIS

Contactar con el soporte técnico

Descargar la aplicación de soporte de Esri

Ir a opciones de descarga