laptop and a wrench

Error

Communications Utility Network Foundation Solution is encountering the "Error 001797: No valid subnetwork controllers found" error while following the task to perform the 'Customer to upstream Switch' trace.

ArcGIS Pro
Número de ID del error BUG-000167050
EnviadoApril 26, 2024
Última modificaciónJuly 9, 2024
Relacionado conArcGIS Pro
Versión encontrada3.2.2
Sistema operativoWindows OS
Versión de sistema operativo10.0 64 Bit
EstadoIn Product Plan

Información adicional

The task calls the models in Communications Trace toolbox. These models leverage the Utility Network Trace GP Tool. The Starting Points input must be mapped to Trace Features\Starting Points but is incorrectly pointing to Wire Cabinets. Adjust the Starting Points input and the task and model succeeds.

Solución alternativa

In the Communications Traces toolbox, open each model and adjust the Starting Points input to point to Trace Features\Starting Points.