After clearing the option of accepting new connections from the Spatial Database Engine (SDE) master schema geodatabase in Oracle, a new connection cannot be made to another user-schema geodatabase using the Create Database Connection tool.

Última publicación: October 24, 2018 ArcSDE/Enterprise Geodatabase
Número de ID del error NIM082761
EnviadoJuly 16, 2012
Última modificaciónApril 2, 2025
Relacionado conArcSDE/Enterprise Geodatabase
Versión encontrada10.1
Sistema operativoWindows OS
Versión de sistema operativo2008 R2 64 Bit
EstadoWill Not Be Addressed

Información adicional

Creating a user-schema geodatabase is likely to be deprecated.

Solución alternativa

Use an existing connection that is set up to use this schema before the master Spatial Database Engine (SDE) schema geodatabase is paused from new connections. Also, change the user name and password to the SDE user temporarily to change the schema, and then change the user name and password back.