Adding a transformer to a conductor line disconnects downstream features from the subnetwork.

Última publicación: October 11, 2022 ArcGIS Pro
Número de ID del error BUG-000152483
EnviadoSeptember 21, 2022
Última modificaciónJune 5, 2024
Relacionado conArcGIS Pro
Versión encontrada2.9.4
Sistema operativoWindows OS
Versión de sistema operativo10.0 64 Bit
EstadoAs Designed

Información adicional

The Connection Point::Overhead Solid Connection placed midspan along the Medium Voltage Conductor does not have Lifecycle Status configured as 'In Service' which makes this a condition barrier as defined in the subnetwork definition for the tier. Updating the Lifecycle Status enables the subnetwork trace to complete and displays the expected Phases Energized on downstream features after running the Update Subnetwork.

Solución alternativa

Configure the Lifecycle Status of the newly placed Connection Point so that it is not a barrier for the subnetwork trace.