Procedure

Summary

Steps to configure a NUMONICS 2000 or 2200 digitizer with 16 or 4-button puck.

Summary

1. Make sure the digitizer is connected to the correct serial port.

2. Make sure the dip switches are set like this:

SWA		SWB		SWC
1 off 1 off 1 on
2 on 2 off 2 off
3 on 3 on 3 off
4 on 4 on 4 off
5 off 5 on
6 on 6 off
7 on 7 on
8 on 8 on

3. Use the following parameters in the CON-DIG setup:

DIGFORM NUMO200P
PORT (port #)
BAUD 9600
PARITY N
DATA BITS 7
STOP BITS 1

4. Edit the NUMO2000 digform as follows and save it as NUMO200P:

'NUMO200P'
1
'(A1,2X,F5.3,T12,F5.3)'
F
F
73.0, 1.0, 0.0
85.0, 1.0, 0.0
12
'0' 0, '1' 1, '2', 2, '3' 3, '4' 4, '5' 5, '6' 6, '7' 7, '8' 8, '9' 9,
'A' 10, 'B' 12
-1
-1
-1
-1
-1

For a digitizer with a 4-button, follow steps 1 and 2. In steps 3 and 4, use NUMO2000 instead of NUMO200P.