HOW TO

Configure an ALTEK AC31 digitizer

Last Published: April 25, 2020

Procedure

Summary

Steps to set up an Altek3 AC31 digitizer.

Procedure

1. Create the following digform file in an text editor and save it as ALTEK31:

8               off             Board type (Datatab)
7 off Menu (disabled)
6 off Tone (disabled)
5 on Run Type (2)
4 off Mode (point)
3 off Mode (point)
2 off Mode (point)
1 off Dipswitch/ No Vram (dipswitch)

8 off Format Number
7 on Format Number
6 off Format Number
5 on Format Number
4 off Format Number
3 off Format Number
2 off Emulation (Altek)
1 off Emulation (Altek)

8 off RTS/CTS (disabled)
7 off Stop bits (1)
6 on Data Bit (8)
5 on Odd/Even
4 off Parity (none)
3 on Baud Rate (9600)
2 off Baud Rate (9600)
1 on Baud Rate (9600)

8 on Line Feed (enabled)
7 off Carriage Return (disabled)
6 off Resolution (1000 lpi)
5 off Resolution (1000 lpi)
4 off Resolution (1000 lpi)
3 off Rate/Increment (2 pts/sec)
2 off Rate/Increment (2 pts/sec)
1 off Rate/Increment (2 pts/sec)

2. Run CON-DIG at the Arc prompt like this:

CON-DIG ALTEK31 x 9600 NONE 8 1
| | | | | |_ stop bits
| | | | |___ data bits
| | | |________ parity
| | |_____________ baud rate
| |_______________ port #
|_______________________ format file