laptop and a wrench

Bug

When using the 'All Bands' processing template when adding Sentinel-2 data (Level 2A) to a mosaic dataset, the mosaic dataset displays as black at the full extent.

Last Published: July 2, 2019 ArcGIS Pro
Bug ID Number BUG-000122692
SubmittedMay 30, 2019
Last ModifiedJune 5, 2024
Applies toArcGIS Pro
Version found2.3.2
Operating SystemWindows OS
Operating System Version10.0 64 Bit
StatusNon-Reproducible

Additional Information

This issue cannot be reproduced in ArcGIS Pro 2.4.

Workaround

Apply a definition query to the mosaic dataset to exclude the SCL-20m and SCL-60m images from the display. These are scene classification layers and are thematic 8-bit layers whereas the other image layers are 16-bit.