laptop and a wrench

Bug

When upgrading Portal for ArcGIS using Powershell DSC version 2.1.0, the PrimaryPortalMachine variable is never assigned a value.

Last Published: October 9, 2019 Portal for ArcGIS
Bug ID Number BUG-000124659
SubmittedAugust 20, 2019
Last ModifiedJune 5, 2024
Applies toPortal for ArcGIS
Version found10.6.1
Operating SystemWindows OS
Operating System Version2016 64 Bit
Version Fixed2.1.1
StatusFixed

Workaround

In line 982 of the ArcGIS.psm1 file (located in the downloaded directory or in C:\Program Files\WindowsPowerShell\Modules\ArcGIS\2.1.0\), replace the value '$HostingConfig.AllNodes.count;' with '$PortalConfig.AllNodes.count;'.

Steps to Reproduce

Bug ID: BUG-000124659

Software:

  • Portal for ArcGIS

Get notified when the status of a bug changes

Download the Esri Support App

Discover more on this topic

Get help from ArcGIS experts

Contact technical support

Download the Esri Support App

Go to download options