When the MAX option is applied in the Option file for ArcInfo workstation, ArcEdit and ArcPlot do not work.
Last Published: August 25, 2014No Product Found
Bug ID Number
NIM007631
Submitted
March 28, 2007
Last Modified
June 5, 2024
Applies to
No Product Found
Version found
9.2
Version Fixed
9.2
Status
Fixed
The bug has been fixed. See the Version Fixed and Additional Information, if applicable, for more information.
Workaround
This is a known issue with the FLEXlm version we use. The way to use the MAX option is to set the MAX value in the options file to n+1 where n is the max number of users you want to restrict usage to. If a client wants to set a restriction to a maximum of 1 person, then the MAX value would be 2.