Bug

When moving a Tower Structure Junction in ArcGIS Pro’s 3D editing environment, Insulator Structure Lines contained within the Insulator Set Structure Edge Object do not consistently follow the tower; some insulators relocate correctly, while others remain at their original location.

ArcGIS Pro
Bug ID Number BUG-000178945
SubmittedAugust 22, 2025
Last ModifiedSeptember 2, 2025
Applies toArcGIS Pro
Version found3.5.3
Operating SystemWindows OS
Operating System Version10.0 64 Bit
StatusWill Not Be Addressed

Additional Information

This issue will not be addressed. The user's model has lines contained in objects that are then contained in junctions, and it is not recommended. The recommendation is to update the data model to contain the structure lines directly in the structure junction (the tower).

Workaround

Move in 2D and adjust z-value manually in the Geometry panel.