laptop and a wrench

Bug

The Upgrade Spatial Reference tool fails when used on a feature dataset containing feature classes with different spatial reference identifiers (SRIDs).

Last Published: June 10, 2019 ArcGIS for Desktop
Bug ID Number BUG-000121059
SubmittedMarch 20, 2019
Last ModifiedJune 5, 2024
Applies toArcGIS for Desktop
Version found10.6.1
Operating SystemWindows OS
Operating System Version2012 R2
StatusNon-Reproducible

Additional Information

The _Upgrade Spatial Reference_ tool is behaving as expected. The reason why it failed is because the wrong XY Resolution was chosen (0.0003125). This XY Resolution value caused the Low Precision Feature Classes to be upgraded to High Precision with an XYUNITS value of 3200, but this value did not match the XYUNITS of 1600 for the existing High Precision Feature Classes that reside in the ElectricDistribution Feature Dataset. To execute the tool successfully, restore the database back to before the tool was previously executed, then run the Upgrade Spatial Reference tool once again, but this time with an XY Resolution of 0.000625. This will upgrade the Low Precision data to High Precision with an XYUNITS value of 1600, which will match the XYUNITS value for the existing High Precision data.

Steps to Reproduce

Bug ID: BUG-000121059

Software:

  • ArcGIS for Desktop

Get notified when the status of a bug changes