laptop and a wrench

Bug

The synchronization process takes around eight hours for 12180 feature edits.

Last Published: July 3, 2015 ArcSDE/Enterprise Geodatabase
Bug ID Number NIM084162
SubmittedAugust 24, 2012
Last ModifiedApril 2, 2025
Applies toArcSDE/Enterprise Geodatabase
Version found10.0
Operating SystemWindows OS
Operating System Version2008 R2 64 Bit
StatusWill Not Be Addressed

Additional Information

Issue with workflow, the two-way replica was used mainly as a one-way from child to parent. Sync the parents first to clean up the parent lineage.

Workaround

Refer to the following steps to synchronize the replica with better performance:1.Delete the orphan sync_receive_rec_976_* expect last sync_receive_rec_976_28 versions using sdevesrion -o delete command.2. Use the sequence below to synchronize the replica:•Sync in the opposite direction first, parent to child.•Next sync the changes from child to parent.