The route analysis layer does not recognize a 3D point restriction barrier when placed over a junction.

ArcGIS Pro
Bug ID Number BUG-000177882
SubmittedJuly 14, 2025
Last ModifiedJuly 28, 2025
Applies toArcGIS Pro
Version found3.5.1
Operating SystemWindows OS
Operating System Version11.0 64 bit
StatusAs Designed

Additional Information

The route avoids point barriers placed on junctions. The project steps show the point being placed on a junction, but the point barrier attribute table shows that the feature is snapped to the line source. A nearby edge, 177 on the floor lines, has the barrier. The route does not go through the barrier, so it appears that the barrier is not honored. Snap the barrier to the junction source to ensure the route honors it.

Workaround

Ensure the barrier is snapped to the junction source, not the line source.

  1. Open the Properties dialog box of the route analysis layer.
  2. In the Properties dialog box, click the Locations tab.
  3. Under 'Define settings for locating inputs on the network', in the drop-down list, select Point Barriers.
  4. Uncheck 'Same as default'.
  5. In the Locatable column, uncheck FloorLines and FloorTransitions, as shown in the image below.