Bug

The DTM generated by Site Scan for ArcGIS contains an incorrect false easting, causing it to be drawn at a different location than the other 2D products.

Site Scan for ArcGIS
Bug ID Number BUG-000164679
SubmittedJanuary 29, 2024
Last ModifiedFebruary 13, 2025
Applies toSite Scan for ArcGIS
Version found4.1.74
Operating SystemWindows OS
Operating System Version10.0 64 Bit
Version FixedArcGIS v3.4.0
StatusFixed

Additional Information

This issue is addressed in ArcGIS Pro 3.4.0.

Workaround

In ArcGIS Pro, use the Define Projection tool on the DTM product to change the spatial reference values to the values used by the orthomosaic and DSM. This method moves the DTM to the correct location.