laptop and a wrench

Bug

Site Scan for ArcGIS does not correctly read coordinate information in NAD 1983 2011 SPCS Alaska Zone 1 (US Feet), ESRI:102445.

Site Scan for ArcGIS
Bug ID Number BUG-000170785
SubmittedSeptember 16, 2024
Last ModifiedJanuary 12, 2025
Applies toSite Scan for ArcGIS
Version found4.6
Operating SystemWindows OS
Operating System Version10.0 64 Bit
StatusNon-Reproducible

Additional Information

Unable to reproduce this issue using the attached data. Please resubmit if the issue remains.

Workaround

Convert the points to meters and use a meter-based coordinate system, such as NAD 1983 (CORS96) SPCS Alaska Zone 1, ESRI:102366. The points can now be uploaded and used successfully. This can be done either manually by converting the feet to points in Excel or by turning points into features in ArcGIS Pro and then using the Project tool to project it.

Steps to Reproduce