laptop and a wrench

Bug

Setting the SQLNET.RECV_TIMEOUT parameter equal to any value other than zero in an Oracle 12c non-pluggable database results in error ORA-28575 when running ST_Geometry extproc queries.

Last Published: July 22, 2016 ArcSDE/Enterprise Geodatabase
Bug ID Number BUG-000097858
SubmittedJuly 18, 2016
Last ModifiedJune 5, 2024
Applies toArcSDE/Enterprise Geodatabase
Version foundN/A
StatusWill Not Be Addressed

Additional Information

We apologize that we were unable to address this issue within the current product support cycle. If the issue continues to affect your work in a supported release, please contact Technical Support.

Workaround

Comment out or do not include a SQLNET.RECV_TIMEOUT parameter in the SQLNET.ora file. Alternatively, set the parameter equal to zero which is the default.