Pan Sharpening does not work correctly when the two datasets are in different coordinate systems or datums.
Last Published: August 25, 2014No Product Found
Bug ID Number
NIM008220
Submitted
April 17, 2007
Last Modified
April 2, 2025
Applies to
No Product Found
Version found
9.2
Version Fixed
9.3
Status
Fixed
The bug has been fixed. See the Version Fixed and Additional Information, if applicable, for more information.
Description
**This bug has been fixed at ArcGIS Desktop 9.3.**
If the RGB and the panchromatic datasets are not in the same coordinate system, the RGB image disappears from the display when attempting to pan-sharpen it.
Cause
This bug is caused by the two datasets being in different coordinate systems.
Workaround
To ensure pan-sharpening works correctly, both images must have the same coordinate system information. Project one of the images to match the other:
Navigate to ArcToolbox > Data Management Tools > Projections and Transformations > Raster and open the Project Raster tool.
Input the raster to project.
Select the output location and name of file.
Select or Import the Spatial Reference so it matches the other image.
Run the tool.
Re-apply pan-sharpening using the two images that are in the same coordinate system.