| Operating System Version | 10.0 |
| Status | Non-Reproducible
This issue was not reproducible when tested by the development team. Issues may be given this status when they cannot be reproduced or are no longer relevant in a development version of the software, but a specific fix was not installed to address the issue. The issue's Additional Information section may contain further explanation.
|
Additional Information
The issue is the BIM file has the length unit set to millimeters and the base point is populated with the values as if units are in meters.
Workaround
- Restart ArcGIS Pro and select Zoom To Layer again.
OR
- Upgrade the Revit file before bringing it into the local scene.
Update the base point values to be millimeters.
Original base point values:
X: 559352.3777
Y: 3700970.4496
The correct values for the base point:
X: 559352377.7
Y: 3700970449.6