laptop and a wrench

Bug

In ArcGIS Enterprise 11.5 Map Viewer, the 'Image measurement' tool remains disabled for oriented imagery layers with the orientation accuracy property defined.

Portal for ArcGIS
Bug ID Number BUG-000180541
SubmittedOctober 29, 2025
Last ModifiedDecember 2, 2025
Applies toPortal for ArcGIS
Version found11.5
Operating SystemWindows Server
Operating System Version2025
StatusKnown Limit

Additional Information

The measurement tool required nine semicolon-separated values instead of the eight specified in the documentation. This issue was known to occur in ArcGIS Enterprise 11.5 and ArcGIS Online 2025 R01, and it has been resolved in ArcGIS Enterprise 12.0 and the latest version of ArcGIS Online.

Workaround

As a workaround, add an additional ;0 at the end of the OrientationAccuracy property. For example, if the current value is 5;10;5;5;5;0;0;1, update the value to 5;10;5;5;5;0;0;1;0. This workaround should work well in ArcGIS Enterprise 11.5.

Steps to Reproduce

Bug ID: BUG-000180541

Software:

  • Portal for ArcGIS

Get notified when the status of a bug changes

Download the Esri Support App