laptop and a wrench

Bug

Feature service reports a completed sync operation even though the database management system (DBMS) user who checked out the replica has no permission to write to the SDE_LOGFILES' table space.

Last Published: March 22, 2017 ArcGIS GIS Server
Bug ID Number BUG-000102280
SubmittedJanuary 20, 2017
Last ModifiedAugust 14, 2025
Applies toArcGIS GIS Server
Version found10.5
Operating SystemWindows OS
Operating System Version10.0
Version Fixed10.6.1
StatusFixed

Workaround

The fix was to recreate the FLDAPPS.SDE_LOGFILES and FLDAPPS.SDE_LOGFILE_DATA tables as temporary tables. Or Ensure the user creating the replica has the privilege to write to the table space housing the SDE_LOGFILES and SDE_LOGFILE_DATA tables.

Steps to Reproduce

Bug ID: BUG-000102280