laptop and a wrench

Bug

Editing the utility network pipeline in ArcGIS Pipeline Referencing (APR) fails and returns the following error message, "Error: Lock request conflicts with an established lock [User transaction in progress - operation not allowed]".

ArcGIS Pro
Bug ID Number BUG-000160710
SubmittedAugust 16, 2023
Last ModifiedJune 11, 2025
Applies toArcGIS Pro
Version found3.1.1
Operating SystemWindows OS
Operating System Version10.0 64 Bit
Version Fixed3.1.7
StatusFixed

Workaround

  1. Delete the linear referencing system (LRS) dataset from the file geodatabase.
  2. Create a new LRS. 
  3. Publish the LRS as a feature service. 

Steps to Reproduce

Bug ID: BUG-000160710

Software:

  • ArcGIS Pro

Get notified when the status of a bug changes

Download the Esri Support App

Discover more on this topic

Get help from ArcGIS experts

Contact technical support

Download the Esri Support App

Go to download options