laptop and a wrench

Bug

ArcGIS Data Store replication failure, upon failover, when using a highly available cloud formation template on Amazon Web Services.

Last Published: April 21, 2023 ArcGIS Data Store
Bug ID Number BUG-000157348
SubmittedApril 8, 2023
Last ModifiedJune 5, 2024
Applies toArcGIS Data Store
Version found10.9.1
Operating SystemWindows Server
Operating System Version2019 64 Bit
StatusAs Designed

Additional Information

ArcGIS Data Store attempts to reconfigure as standby by replaying logs in a timeline in the event of a failover. If the standby cannot catch up to the timeline after being offline, then an error is logged, such as "Replication could not catch up with Primary machine". The standby in this event needs to be reconfigured.

Workaround

  1. Unregister ArcGIS Data Store from new standby.
  2. Uninstall ArcGIS Data Store from new standby.
  3. Reinstall and reregister new standby ArcGIS Data Store.

Steps to Reproduce

Bug ID: BUG-000157348