laptop and a wrench

Bug

After installing ArcGIS Server 10.8.1 Utility Network Patch 6, the Validate Network Topology tool returns the message, "ERROR 002981: Value exceeds valid range of column".

Last Published: March 3, 2022 ArcGIS Utility Network
Bug ID Number BUG-000147284
SubmittedMarch 2, 2022
Last ModifiedJanuary 26, 2026
Applies toArcGIS Utility Network
Version found4
Operating SystemWindows OS
Operating System Version10.0
StatusNon-Reproducible

Additional Information

The last reproducible case of this failure occurred in Utility Network patches for ArcGIS Enterprise 10.8.1. As of the 10.9.1 release, this failure is no longer encountered. ArcGIS Enterprise 10.8.1 is no longer supported. Move to a supported release if encountering this failure.

Workaround

  • When network topology validation fails, disable and re-enable network topology to get the Validate Network Topology tool to run successfully.
  • Remove ArcGIS Server 10.8.1 Utility Network Patch 6 and install ArcGIS Server 10.8.1 Utility Network Patch 5B.

Steps to Reproduce