laptop and a wrench

Bug

When the error "25: Stacked point features" is returned in a utility network, and the Terminal Path is set to null, the error "39: Point feature has invalid terminal configuration" is also returned. The errors cannot be resolved without first resolving error ID 25 by dropping and re-enabling the network topology.

ArcGIS Pro
Bug-ID-Nummer BUG-000164281
EingereichtJanuary 11, 2024
Zuletzt geändertFebruary 7, 2024
Gilt fürArcGIS Pro
Gefunden in Version3.2
BetriebssystemWindows OS
Betriebssystemversion10.0 64 Bit
StatusIn Review

Workaround

To remove the error, replace the null Terminal Path with 'Default', drop the network topology, and re-enable it. Move the overlapping points responsible for error ID 25 to also remove error ID 39. 

Schritte zur Reproduzierung

Bug-ID: BUG-000164281