laptop and a wrench

Bug

When converting a feature class from PGDB to SDE, a field type Float converts to a Double with extra values.

Zuletzt veröffentlicht: August 25, 2014 No Product Found
Bug-ID-Nummer NIM010927
EingereichtAugust 13, 2007
Zuletzt geändertApril 28, 2025
Gilt fürNo Product Found
Gefunden in Version9.2
StatusWill Not Be Addressed

Zusätzliche Informationen

No Public Explanation

Workaround

1. Create an empty feature class in SDE geodatabase with same spatial reference as that of the PGDB feature class.2. While creating, Import the fields from the PGDB feature class.3. For Float fields, choose precision and scale as per the requirement (say, precision-5, scale-2)4. Click “Finish” to create the feature class.5. Check again by right clicking the feature class that the Float fields are maintained.6. Now, load the data into this feature class from the PGDB feature class by simple data loader in ArcCatalog. Right click on the feature class? Load Data7. This method retains the original names of the fields.Per Nana Dei:For SQL Server: When the column is created with the ‘REAL’ data type, it shows as Float from ArcCatalogHowever, when it is created as ‘Float’ from ArcCatalog is shows as DOUBLE in ArcCatalog 10 and NUMERIC in SQL Server.

Schritte zur Reproduzierung

Bug-ID: NIM010927

Software:

  • No Product Found

Benachrichtigung erhalten, wenn sich der Status eines Bugs ändert

Esri Support App herunterladen

Weitere Informationen zu diesem Thema erkunden

Unterstützung durch ArcGIS-Experten anfordern

An den technischen Support wenden

Esri Support App herunterladen

Zu Download-Optionen wechseln