Tracing connected features in a Utility Network from a barrier with two terminals does not traverse the opposite terminal.

ArcGIS Pro
Bug-ID-Nummer BUG-000165667
EingereichtMarch 6, 2024
Zuletzt geändertJune 5, 2024
Gilt fürArcGIS Pro
Gefunden in Version3.2.2
BetriebssystemWindows OS
Betriebssystemversion10.0 64 Bit
StatusAs Designed

Zusätzliche Informationen

In this scenario, a Condition barrier is configured for both the IN and OUT terminals (Asset Group is equal to Indeterminate) on the device, whereas a Starting point is only present on the IN terminal. Ignore Starting Points at Barriers is honored properly in this case but does not apply to the OUT terminal which also has a barrier present. This is what led to the trace result reported.

Workaround

Place a second starting point on the other terminal (so that both the IN and OUT terminals have starting points) and run the trace again with the Ignore Barriers at Starting Points parameter checked.